Graphical Reports
 FACILITY REQUIREMENTS    Computer    System Software    S&A 250B or 250C Network Analyzer    Direct Drive Roughing Pump    Cryo, Diffusion or Turbo Pump  SYSTEM CONFIGURATION    Power:  220 or 380 Volts, 3-Phase, 15 Amps    Inlet Pressures:  150 PSIG Maximum    Air:  90 PSIG    Nitrogen:  20 PSIG    Water Cooling (Diffusion):  0.15 GPM @ 60 - 80 Deg. F (16-27 Deg. C)    Dimensions:  22 x 70 x 40 inches (54.6 x 177.8 x 101.6 cm)  6300344-01  SCREEN FORMAT
Magnetic Wheel
Plating System
 SPECIFICATIONS  S&A             W-5250S
PLATING SYSTEM
   Quartz crystal final frequency adjust plating system    Vertical evaporation and pulse width modulation of
filament power results in minimal plating material usage
   Single aperture with three axis adjustment for simple  
plating spot alignment
   Precision plating to load resonant frequency
using "Measured FL" method
   No physical capacitor required    Over 40 different crystal parameter measurements,  including DLD and Spurious    S&A 2296 Heater Kit for plating at crystal
turning point temperature
 250B Frequency Range:  0.5 MHz -  200 MHz  250C Frequency Range:  0.5 MHz -  500 MHz  Plating Performan ce:  ± 1 ppm  typical final frequency
± .1 ppm  with S&A 2296 Heater Kit Option
 Throughput:  500 units/hour (100 Position Wheel)
400 units/hour (50 Position Wheel)
   Proprietary magnetic wheel uses no sockets    Contacts directly to crystal leads    Standard wheel holds 50 devices and
accepts HC-45 and HC-49 type packages
   100 Position HC-49US wheel available    Various HC-family, SMD and custom
wheels available